DAIKIN SENSIRA FTXF-D 3.5KW (A++/A+) INCL. WIFI

Sale price€970,00
Re-stocking soon
Split-unit single unit: No installation, Pick up at Head Office Tegelen

Split-unit single unit


Wall-mounted unit

Sensira - FTXF-D

Wall-mounted unit for low energy consumption and pleasant comfort

 

Product features

  • Seasonal efficiency up to A++ in cooling mode
  • Daikin Residential Controller (optional): control your indoor unit from any location using an app, via your local network or the internet.
  • Whisper-quiet operation, down to just 20 dBA
  • Choose an R-32 product to reduce your environmental impact by 68% compared to R-410A systems and directly reduce your energy consumption, thanks to its high energy efficiency.

Product Information

Wall-mounted unit

Sensira - FTXF-D

Wall-mounted unit for low energy consumption and comfortable indoor climate

 

Product features

  • Seasonal efficiency up to A++ in cooling mode
  • Daikin Residential Controller (optional): control your indoor unit from any location with an app, via your local network or the internet.
  • Whisper-quiet operation, down to just 20 dBA
  • Choose an R-32 product to reduce your environmental impact by 68% compared to R-410A systems and directly reduce your energy consumption, thanks to its high energy efficiency.

Benefits

  •  

Onecta app (optional)

Control your indoor climate anywhere via a smartphone or tablet

  •  

Energy-saving standby mode (Class 25 + 35)

In standby, power consumption drops by approximately 80%.

  •  

Econo mode (Class 25 + 35)

Decreases power consumption so that other systems with high power consumption can be used. This function also saves energy.

Fan only mode

The unit can be used as a fan, circulating the air in the room without heating or cooling it.

  •  

Comfort mode (Class 25 + 35)

Ensures that cold drafts are minimised by preventing warm or cool air from being directed directly at people in the room.

  •  

POWER mode

Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original settings.

  •  

Automatic cooling/heating changeover

Automatically switches between heating and cooling to achieve the preset temperature.

  •  

Whisper-quiet operation of the indoor unit

"Silent" buttons on the remote control reduce the indoor unit's operating sound by 3dB(A)

  •  

Vertical auto-swing

Ability to automatically move the discharge louvres vertically, for an even airflow and temperature distribution in the room.

  •  

Automatic fan speed

Automatically selects the appropriate fan speed to reach or maintain the set temperature.

  •  

Fan speeds (5 steps)

All specified fan speeds can be selected with a single button.

  •  

Dry program

This function reduces humidity without varying room temperature.

  •  

Air filter

Captures the smallest dust particles to ensure a constant supply of clean air.

  •  

24-hour timer

Programmable so that the unit starts heating or cooling at a specific time within a 24-hour period.

  •  

Infrared remote control

Starts, stops, and controls the air conditioner remotely.

  •  

Automatic restart

After a power failure, the indoor unit automatically restarts with the original settings.

  •  

Malfunction diagnosis

Simplifies maintenance by indicating system faults or operational malfunctions.

Technical data table for FTXF-D

 

FTXF20D5V1B

FTXF25D5V1B

FTXF35D5V1B

FTXF42D5V1B

FTXF50D2V1B

FTXF60D2V1B

FTXF71D2V1B

Sound pressure level at 1m

Heating

High

dB(A)

39.0

40.0

40.0

44.0

42

44

45

 

 

Mid

dB(A)

34.0

34.0

35.0

34.0

38

40

41

 

 

Quiet operation

dB(A)

21.0

21.0

21.0

22.0

30

32

33

 

 

Low

dB(A)

28.0

28.0

29.0

28.0

33

35

36

 

Cooling

Mid

dB(A)

33.0

33.0

34.0

36.0

39

41

42

 

 

Quiet operation

dB(A)

20.0

20.0

20.0

22.0

31

33

34

 

 

Low

dB(A)

25.0

26.0

27.0

30.0

34

36

37

 

 

High

dB(A)

39.0

40.0

43.0

45.0

43

45

46

Standard accessories

AAA dry cell battery

2

2

2

2

2

2

2

 

Installation manual

1

1

1

1

1

1

1

 

Operating manual

1

1

1

1

1

1

1

 

Infrared remote control

1

1

1

1

1

1

1

 

Remote control holder

1

1

1

1

1

1

1

 

Mounting plate

1

1

1

1

1

1

1

 

Indoor unit mounting screws

2

2

2

2

2

2

2

Control systems

Wired remote control

 

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

 

IR remote control

 

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

Piping connections

Liquid

OD

mm

6

6

6

6

6.35

6.35

6.35

 

Gas

 

mm

9.50

9.50

9.50

9.50

12.7

12.7

12.7

 

Drain

 

18

18

18

18

18

18

18

Power input

Cooling

Nom.

kW

0.023

0.023

0.029

0.040

0.029

0.032

0.032

 

Heating

Nom.

kW

0.023

0.023

0.029

0.040

0.032

0.035

0.035

Sound power level

Cooling

dB(A)

53.0

54.0

54.0

59.0

59

60

62

 

Heating

dB(A)

55.0

55.0

56.0

59.0

61

62

62

Dimensions

Unit

Width

mm

770

770

770

770

990

990

990

 

 

D

mm

225

225

225

225

263

263

263

 

 

Height

mm

286

286

286

286

295

295

295

Casing

Colour

 

White

White

White

White

White

White

White

Weight

Unit

kg

8.00

8.00

8.50

9.00

13.5

13.5

13.5

Fan

Air flow rate

Heating

High

m³/min

10.4

10.4

11.9

12.8

17.3

17.9

17.9

 

 

 

Medium-high

m³/min

8.3

8.4

8.6

8.8

14.8

15.8

15.8

 

 

 

Low

m³/min

6.2

6.4

6.5

6.7

12.2

12.8

12.8

 

 

 

Silent operation

m³/min

5.3

5.3

5.3

5.2

10.7

11.3

11.3

 

 

Cooling

Low

m³/min

6.0

6.2

6.4

6.9

11.9

12.2

12.2

 

 

 

Medium-high

m³/min

8

8

8

9

14.4

14.8

14.8

 

 

 

High

m³/min

9.8

10.0

11.5

12.6

16.8

17.3

17.3

 

 

 

Silent operation

m³/min

4.3

4.3

4.4

4.9

10.5

10.7

10.7

Power supply

Phase

 

1~

1~

1~

1~

1~

1~

1~

 

Name

 

 

 

 

 

V1

V1

V1

 

Frequency

Hz

50

50

50

50

50

50

50

 

Voltage

V

220-440

220-440

220-440

220-440

220-240

220-240

220-240

Standard accessories

Batteries

1

1

1

1

     

 

General precautions

196

196

196

196

     

Notes

(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

     

 

(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

     

 

(3) - For electrical data, see separate drawing

(3) - For electrical data, see separate drawing

(3) - For electrical data, see separate drawing

(3) - For electrical data, see separate drawing