DAIKIN SENSIRA FTXF-D 5.0KW (A++/A+) INCL. WIFI

Sale price€1.321,00
Re-stocking soon
Split-unit single unit: No installation, Pick up Head office Tegelen

Split-unit single unit


Daikin Sensira FTXF-D 5.0kW – Powerful and Energy-Efficient Air Conditioner for Large SpacesThe Daikin Sensira FTXF-D 5.0kW offers A++ energy efficiency and is ideal for large spaces. This model provides powerful cooling and heating, making it a perfect solution for regulating the temperature in larger living or working areas. The air purification function ensures that the air remains clean, while its quiet operation provides a comfortable and peaceful environment.With its smooth airflow and simple remote control operation, the Daikin Sensira FTXF-D 5.0kW is both user-friendly and effective. This model ensures you enjoy optimal comfort and energy efficiency all year round.Product features:✅ Power: 5.0 kW – perfect for larger spaces✅ A++ energy efficiency – save on energy costs✅ Smooth airflow for a comfortable experience✅ Quiet operation – sound pressure level of only 21 dBA✅ Easy remote control operation✅ Reliable cooling and heating for year-round comfort✅ Air purification function for healthy air in larger spacesThe Daikin Sensira FTXF-D 5.0kW offers powerful performance, energy efficiency, and comfort, making it an excellent choice for large spaces.

Product Information

Wall-mounted unit

Sensira - FTXF-D

Wall-mounted unit for low energy consumption and comfortable indoor climate

 

Product features

  • Seasonal efficiency up to A++ in cooling mode
  • Daikin Residential controller (optional): control your indoor unit from anywhere with an app, via your local network or the internet.
  • Whisper-quiet operation, down to just 20 dBA
  • Choose an R-32 product to reduce your environmental impact by 68% compared to R-410A systems and directly reduce your energy consumption, thanks to its high energy efficiency.

Benefits

  •  

Onecta app (optional)

Control your indoor climate anywhere via a smartphone or tablet

  •  

Energy-saving standby mode (Class 25 + 35)

In standby, power consumption drops by approximately 80%.

  •  

Econo mode (Class 25 + 35)

Reduces power consumption, allowing other high-power consumption systems to be used. This function also saves energy.

Fan only mode

The unit can be used as a fan, allowing air to circulate in the room without heating or cooling it.

  •  

Comfort mode (Class 25 + 35)

Ensures that cold drafts are minimised by preventing hot or cold air from being directed directly at occupants.

  •  

POWER mode

Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original setting.

  •  

Automatic cooling/heating changeover

Automatically switches between heating and cooling to maintain the preset temperature.

  •  

Whisper-quiet operation of the indoor unit

"Silent" buttons on the remote control reduce the indoor unit's operating noise by 3dB(A)

  •  

Vertical auto-swing

Ability to automatically move the air discharge flaps vertically, for an even airflow and temperature distribution in the room.

  •  

Automatic fan speed

Automatically selects the appropriate fan speed to achieve or maintain the set temperature.

  •  

Fan speeds (5 steps)

All specified fan speeds can be selected with a single button.

  •  

Dry program

This function reduces humidity without variations in room temperature.

  •  

Air filter

Captures the smallest dust particles to ensure a constant supply of clean air.

  •  

24-hour timer

Programmable to start heating or cooling at a specific time within a 24-hour period.

  •  

Infrared remote control

Starts, stops, and controls the air conditioner remotely.

  •  

Automatic restart

After a power failure, the indoor unit automatically restarts with the original settings.

  •  

Fault diagnosis

Simplifies maintenance by indicating system faults or operating anomalies.

Technical data table for FTXF-D

 

FTXF20D5V1B

FTXF25D5V1B

FTXF35D5V1B

FTXF42D5V1B

FTXF50D2V1B

FTXF60D2V1B

FTXF71D2V1B

Sound pressure level at 1 m

Heating

High

dB(A)

39.0

40.0

40.0

44.0

42

44

45

 

 

Medium

dB(A)

34.0

34.0

35.0

34.0

38

40

41

 

 

Quiet operation

dB(A)

21.0

21.0

21.0

22.0

30

32

33

 

 

Low

dB(A)

28.0

28.0

29.0

28.0

33

35

36

 

Cooling

Medium

dB(A)

33.0

33.0

34.0

36.0

39

41

42

 

 

Quiet operation

dB(A)

20.0

20.0

20.0

22.0

31

33

34

 

 

Low

dB(A)

25.0

26.0

27.0

30.0

34

36

37

 

 

High

dB(A)

39.0

40.0

43.0

45.0

43

45

46

Standard accessories

AAA dry cell battery

2

2

2

2

2

2

2

 

Installation manual

1

1

1

1

1

1

1

 

Operating manual

1

1

1

1

1

1

1

 

Infrared remote control

1

1

1

1

1

1

1

 

Remote control holder

1

1

1

1

1

1

1

 

Mounting plate

1

1

1

1

1

1

1

 

Indoor unit mounting screws

2

2

2

2

2

2

2

Control systems

Wired remote control

 

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

BRC073A1

 

IR remote control

 

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

ARC470A1

Piping connections

Liquid

OD

mm

6

6

6

6

6.35

6.35

6.35

 

Gas

 

mm

9.50

9.50

9.50

9.50

12.7

12.7

12.7

 

Drain

 

18

18

18

18

18

18

18

Power consumption

Cooling

Nom.

kW

0.023

0.023

0.029

0.040

0.029

0.032

0.032

 

Heating

Nom.

kW

0.023

0.023

0.029

0.040

0.032

0.035

0.035

Sound power level

Cooling

dB(A)

53.0

54.0

54.0

59.0

59

60

62

 

Heating

dB(A)

55.0

55.0

56.0

59.0

61

62

62

Dimensions

Unit

Width

mm

770

770

770

770

990

990

990

 

 

D

mm

225

225

225

225

263

263

263

 

 

Height

mm

286

286

286

286

295

295

295

Casing

Colour

 

White

White

White

White

White

White

White

Weight

Unit

kg

8.00

8.00

8.50

9.00

13.5

13.5

13.5

Fan

Airflow rate

Heating

High

m³/min

10.4

10.4

11.9

12.8

17.3

17.9

17.9

 

 

 

Medium-High

m³/min

8.3

8.4

8.6

8.8

14.8

15.8

15.8

 

 

 

Low

m³/min

6.2

6.4

6.5

6.7

12.2

12.8

12.8

 

 

 

Quiet operation

m³/min

5.3

5.3

5.3

5.2

10.7

11.3

11.3

 

 

Cooling

Low

m³/min

6.0

6.2

6.4

6.9

11.9

12.2

12.2

 

 

 

Medium-High

m³/min

8

8

8

9

14.4

14.8

14.8

 

 

 

High

m³/min

9.8

10.0

11.5

12.6

16.8

17.3

17.3

 

 

 

Quiet operation

m³/min

4.3

4.3

4.4

4.9

10.5

10.7

10.7

Power supply

Phase

 

1~

1~

1~

1~

1~

1~

1~

 

Name

 

 

 

 

 

V1

V1

V1

 

Frequency

Hz

50

50

50

50

50

50

50

 

Voltage

V

220-440

220-440

220-440

220-440

220-240

220-240

220-240

Standard accessories

Batteries

1

1

1

1

     

 

General precautions

196

196

196

196

     

Remarks

(1) - Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

(1) - Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent pipe length: 5 m; height difference: 0m

     

 

(2) - Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

(2) - Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5 m (horizontal)

     

 

(3) - For electrical data, refer to separate drawing

(3) - For electrical data, refer to separate drawing

(3) - For electrical data, refer to separate drawing

(3) - For electrical data, refer to separate drawing