
















DAIKIN PERFERA INDOOR 5.0KW (A+++/A+++)

Product Information
Product information
Wall mounted unit
Perfera - FTXM-R
Attractive wall mounted unit delivers perfect air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost quickly heats up your home after the start-up of your air conditioner. Set temperature is reached 14% faster than with a normal air conditioner (pair only)
- Flash streamer uses electrons to trigger chemical reactions with air borne particles, to break down allergens such as pollen and fungal allergens and remove bothersome odours providing a better, cleaner air
- Silver allergen filter & air purification captures allergens such as pollen to ensure a steady supply of clean air
- Daikin Residential controller: control your indoor unit from any location with an app, via your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
- Quiet operation: sound pressure level down to 19 dBA
- 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large rooms.
- 2-area motion detection sensor: air flow is sent to a zone other than where the person is currently located; if no people are detected, the unit will automatically switch over to energy-efficient setting. (larger power range)
Benefits
Silver allergen filter & air purification
Captures allergens such as pollen to ensure a steady supply of clean air
Whisper quiet operation
Whisper quiet operation: unit runs so quietly that you will barely notice it is there.
Multi-split application
Up to 5 indoor units, even with different capacities, can be connected to 1 outdoor unit. All indoor units can be operated individually within the same mode (heating or cooling).
Heat boost
Quickly heats up your home after the start-up of your air conditioner. Set temperature is reached 20% faster than with a normal air conditioner (pair only)
Onecta App
Control your indoor from any location via smartphone or tablet
Econo mode
Decreases power consumption, enabling other apparatuses with high power consumption to be used. This function also saves energy.
2-area motion detection sensor
Air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting.
Energy saving during standby mode
Current consumption is reduced by about 80% when operating in standby mode.
Night set mode
Saves energy by preventing overcooling or overheating during night time.
Fan only
The unit can be used as a fan, circulating the air in the room without heating or cooling.
Comfort mode
Guarantees draught-free operation by preventing that warm or cold air is directly blown onto a person.
POWERFUL mode
Can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.
Automatic cooling-heating changeover
Automatically selects cooling or heating mode to achieve the set temperature.
Indoor unit silent operation
"Silent" button on the remote control lowers the indoor unit's operation sound by 3dB(A)
Outdoor unit silent operation
"Silent" button on the remote control lowers the outdoor unit's operation sound by 3dB(A) to ensure a quiet environment for the neighbourhood.
3-D air flow
Combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large rooms.
Vertical auto swing
Ability to select automatic vertical moving of the air discharge flaps, for efficient air and temperature distribution throughout the room.
Horizontal auto swing
Ability to select automatic horizontal moving of the air discharge louvre, for efficient air and temperature distribution throughout the room.
Automatic fan speed
Automatically selects the necessary fan speed to reach or maintain the set temperature.
Fan speed steps (5 steps)
Allows to select up to the given number of fan speed.
Dry programme
Reduces humidity levels without variations in room temperature.
Flash streamer
Flash streamer uses electrons to trigger chemical reactions with air borne particles, to break down allergens such as pollen and fungal allergens and remove bothersome odours providing a better, cleaner air
Titanium apatite deodorising filter
Breaks down bothersome odours of for example tobacco and pets
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Weekly timer
Can be set to start heating or cooling at any time on a daily or weekly basis.
24 hour timer
Can be set to start operation any time during a 24 hour period.
Infrared remote control
Starts, stops and regulates the air conditioner from a distance.
Wired remote control
Starts, stops and regulates the air conditioner.
Central remote control
Starts, stops and regulates several air conditioners from one central point.
Auto-restart
The unit restarts automatically at the original settings after power failure.
Self-diagnosis
Simplifies maintenance by indicating system faults or operating anomalies.
Technical data table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level @ 1m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Medium-high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Quiet |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Medium-high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Quiet |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard Accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote controller |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote controller holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Mounting screws Indoor unit |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adaptor kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
D |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium High |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Silent operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium High |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Silent operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Notes |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|
Standard accessories |
Silver particle filter |
|
|
|
|
|
|
1 |
1 |
1 |
|||||
VIDEO
https://youtu.be/O0B0xmCuLE4
Specifications
No specifications.
Wall mounted unit
Perfera - FTXM-R
Attractive wall mounted unit delivers perfect air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost quickly heats up your home after the start-up of your air conditioner. Set temperature is reached 14% faster than with a normal air conditioner (pair only)
- Flash streamer uses electrons to trigger chemical reactions with air borne particles, to break down allergens such as pollen and fungal allergens and remove bothersome odours providing a better, cleaner air
- Silver allergen filter & air purification captures allergens such as pollen to ensure a steady supply of clean air
- Daikin Residential controller: control your indoor unit from any location with an app, via your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
- Quiet operation: sound pressure level down to 19 dBA
- 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large rooms.
- 2-area motion detection sensor: air flow is sent to a zone other than where the person is currently located; if no people are detected, the unit will automatically switch over to energy-efficient setting. (larger power range)
Benefits
Silver allergen filter & air purification
Captures allergens such as pollen to ensure a steady supply of clean air
Whisper quiet operation
Whisper quiet operation: unit runs so quietly that you will barely notice it is there.
Multi-split application
Up to 5 indoor units, even with different capacities, can be connected to 1 outdoor unit. All indoor units can be operated individually within the same mode (heating or cooling).
Heat boost
Quickly heats up your home after the start-up of your air conditioner. Set temperature is reached 20% faster than with a normal air conditioner (pair only)
Onecta App
Control your indoor from any location via smartphone or tablet
Econo mode
Decreases power consumption, enabling other apparatuses with high power consumption to be used. This function also saves energy.
2-area motion detection sensor
Air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting.
Energy saving during standby mode
Current consumption is reduced by about 80% when operating in standby mode.
Night set mode
Saves energy by preventing overcooling or overheating during night time.
Fan only
The unit can be used as a fan, circulating the air in the room without heating or cooling.
Comfort mode
Guarantees draught-free operation by preventing that warm or cold air is directly blown onto a person.
POWERFUL mode
Can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.
Automatic cooling-heating changeover
Automatically selects cooling or heating mode to achieve the set temperature.
Indoor unit silent operation
"Silent" button on the remote control lowers the indoor unit's operation sound by 3dB(A)
Outdoor unit silent operation
"Silent" button on the remote control lowers the outdoor unit's operation sound by 3dB(A) to ensure a quiet environment for the neighbourhood.
3-D air flow
Combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large rooms.
Vertical auto swing
Ability to select automatic vertical moving of the air discharge flaps, for efficient air and temperature distribution throughout the room.
Horizontal auto swing
Ability to select automatic horizontal moving of the air discharge louvre, for efficient air and temperature distribution throughout the room.
Automatic fan speed
Automatically selects the necessary fan speed to reach or maintain the set temperature.
Fan speed steps (5 steps)
Allows to select up to the given number of fan speed.
Dry programme
Reduces humidity levels without variations in room temperature.
Flash streamer
Flash streamer uses electrons to trigger chemical reactions with air borne particles, to break down allergens such as pollen and fungal allergens and remove bothersome odours providing a better, cleaner air
Titanium apatite deodorising filter
Breaks down bothersome odours of for example tobacco and pets
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Weekly timer
Can be set to start heating or cooling at any time on a daily or weekly basis.
24 hour timer
Can be set to start operation any time during a 24 hour period.
Infrared remote control
Starts, stops and regulates the air conditioner from a distance.
Wired remote control
Starts, stops and regulates the air conditioner.
Central remote control
Starts, stops and regulates several air conditioners from one central point.
Auto-restart
The unit restarts automatically at the original settings after power failure.
Self-diagnosis
Simplifies maintenance by indicating system faults or operating anomalies.
Technical data table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level @ 1m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Medium-high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Quiet |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Medium-high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Quiet |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard Accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote controller |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote controller holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Mounting screws Indoor unit |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adaptor kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
D |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium High |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Silent operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium High |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Silent operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Notes |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|
Standard accessories |
Silver particle filter |
|
|
|
|
|
|
1 |
1 |
1 |
|||||
VIDEO
https://youtu.be/O0B0xmCuLE4
No specifications.