Attractive wall-mounted unit ensures perfect indoor air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost heats your home quickly after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (for pairs only)
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould and removing unpleasant odours to provide a better, cleaner air.
- The silver allergen removal and air purification filter captures allergens such as pollen to ensure a constant supply of clean air.
- Daikin Residential Controller: control your indoor unit from any location via an app, through your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control key functions such as set point, operation mode, fan speed, etc.
- Quiet operation: sound pressure level down to just 19 dBA
- 3D air flow combines vertical and horizontal auto-swing and ensures that the warm or cool air stream reaches even the furthest corners in large rooms.
- 2-area motion sensor: the air flow is always directed to a zone where no person is present; When no people are detected, the unit automatically switches to energy-saving mode. (larger capacity area)
Benefits
Silver allergen removal and air purification filter
Removes allergens such as pollen to ensure a constant supply of clean air.
Almost inaudible
Almost inaudible: the unit operates so quietly that you forget it's there.
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Heat boost
Heats your home quickly after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (for pairs only).
Onecta App
Control your indoor climate anywhere via a smartphone or tablet.
Econo mode
Reduces power consumption, allowing other high-power consumption systems to be used. This function is also energy-saving.
2-area motion sensor
The airflow is always directed to a zone where no person is present. When no people are detected, the unit automatically switches to energy-saving mode.
Energy-saving standby mode
In standby, power consumption is reduced by approximately 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, allowing air to circulate in the room without heating or cooling it.
Comfort mode
Ensures that cold draughts are minimised by preventing warm or cool air from being directed directly at occupants.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original settings.
Automatic heating/cooling changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Indoor unit quiet operation
"Silent" buttons on the remote control reduce the indoor unit's operating noise by 3dB(A).
Outdoor unit extra quiet function
The "Silent" button on the remote control reduces the outdoor unit's operating noise by 3dB(A) to avoid disturbing the neighbourhood.
3-D airflow
Combines vertical and horizontal auto-swing and ensures that the warm or cool air stream reaches even the furthest corner in large rooms.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically, for an even airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge blade horizontally, creating an even airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to achieve or maintain the set temperature.
Fan speeds (5 steps)
All specified fan speeds can be selected with a single key.
Dry programme
This function reduces humidity without variations in room temperature.
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould and removing unpleasant odours to provide a better, cleaner air.
Titanium apatite deodorising filter
Decomposes unpleasant odours from, for example, tobacco and pets.
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The timer for heating or cooling can be set for any time of day or weekly.
24-hour timer
Programmable to start heating or cooling at a specific time within a 24-hour period.
Infrared remote control
Starts, stops and controls the air conditioner remotely.
Wired remote control
Starts, stops and controls the air conditioner.
Central remote control
For remotely starting, stopping and controlling multiple air conditioners from a central point.
Auto-restart
After a power failure, the indoor unit automatically restarts with its original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operating malfunctions.
Technical data table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level at 1m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Mid-high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Quiet operation |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Mid-high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Quiet operation |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operating manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Mounting screws Indoor Unit |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adapter kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
D |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Air flow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium high |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Quiet operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium high |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Quiet operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|
Standard accessories |
Silver particle filter |
|
|
|
|
|
|
1 |
1 |
1 |
|||||
VIDEO
https://youtu.be/O0B0xmCuLE4
Specifications
No specifications.
Wall-mounted unit
Perfera - FTXM-R
Attractive wall-mounted unit ensures perfect indoor air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost heats your home quickly after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (for pairs only)
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould and removing unpleasant odours to provide a better, cleaner air.
- The silver allergen removal and air purification filter captures allergens such as pollen to ensure a constant supply of clean air.
- Daikin Residential Controller: control your indoor unit from any location via an app, through your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control key functions such as set point, operation mode, fan speed, etc.
- Quiet operation: sound pressure level down to just 19 dBA
- 3D air flow combines vertical and horizontal auto-swing and ensures that the warm or cool air stream reaches even the furthest corners in large rooms.
- 2-area motion sensor: the air flow is always directed to a zone where no person is present; When no people are detected, the unit automatically switches to energy-saving mode. (larger capacity area)
Benefits
Silver allergen removal and air purification filter
Removes allergens such as pollen to ensure a constant supply of clean air.
Almost inaudible
Almost inaudible: the unit operates so quietly that you forget it's there.
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Heat boost
Heats your home quickly after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (for pairs only).
Onecta App
Control your indoor climate anywhere via a smartphone or tablet.
Econo mode
Reduces power consumption, allowing other high-power consumption systems to be used. This function is also energy-saving.
2-area motion sensor
The airflow is always directed to a zone where no person is present. When no people are detected, the unit automatically switches to energy-saving mode.
Energy-saving standby mode
In standby, power consumption is reduced by approximately 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, allowing air to circulate in the room without heating or cooling it.
Comfort mode
Ensures that cold draughts are minimised by preventing warm or cool air from being directed directly at occupants.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original settings.
Automatic heating/cooling changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Indoor unit quiet operation
"Silent" buttons on the remote control reduce the indoor unit's operating noise by 3dB(A).
Outdoor unit extra quiet function
The "Silent" button on the remote control reduces the outdoor unit's operating noise by 3dB(A) to avoid disturbing the neighbourhood.
3-D airflow
Combines vertical and horizontal auto-swing and ensures that the warm or cool air stream reaches even the furthest corner in large rooms.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically, for an even airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge blade horizontally, creating an even airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to achieve or maintain the set temperature.
Fan speeds (5 steps)
All specified fan speeds can be selected with a single key.
Dry programme
This function reduces humidity without variations in room temperature.
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould and removing unpleasant odours to provide a better, cleaner air.
Titanium apatite deodorising filter
Decomposes unpleasant odours from, for example, tobacco and pets.
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The timer for heating or cooling can be set for any time of day or weekly.
24-hour timer
Programmable to start heating or cooling at a specific time within a 24-hour period.
Infrared remote control
Starts, stops and controls the air conditioner remotely.
Wired remote control
Starts, stops and controls the air conditioner.
Central remote control
For remotely starting, stopping and controlling multiple air conditioners from a central point.
Auto-restart
After a power failure, the indoor unit automatically restarts with its original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operating malfunctions.
Technical data table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level at 1m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Mid-high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Quiet operation |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Mid-high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Quiet operation |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operating manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Mounting screws Indoor Unit |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adapter kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
D |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Air flow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium high |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Quiet operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium high |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Quiet operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|