DAIKIN PERFERA INDOOR 4.2KW (A+++/A+++)

Product Information
Product information
Wall-mounted unit
Perfera - FTXM-R
Attractive wall-mounted unit ensures perfect indoor air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost quickly heats up your home when starting your air conditioner. Set temperature is reached 14% faster than with a normal air conditioner (pair only)
- Flash Streamer uses electrons to trigger chemical reactions with air-borne particles, breaking down allergens such as pollen and mould and removing bothersome odours to provide better, cleaner air
- The silver allergen removal and air purification filter captures allergens such as pollen to ensure a steady supply of clean air
- Daikin Residential Controller: control your indoor unit from any location via app, your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc.
- Quiet operation: sound pressure level down to 19 dBA
- 3D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
- 2-area motion sensor: air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting. (larger capacity area)
Benefits
Silver allergen removal and air purification filter
Captures allergens such as pollen to ensure a steady supply of clean air
Whisper quiet
Whisper quiet: the unit runs so quietly you'll forget it's even there.
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Heat boost
Quickly heats up your home when starting your air conditioner. Set temperature is reached 20% faster than with a normal air conditioner (pair only)
Onecta App
Control your indoor climate from any location via smartphone or tablet
Econo mode
Decreases power consumption so that other high power consumption appliances can be used. This function is also energy-saving.
2-area motion sensor
Air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting.
Energy-saving standby mode
Power consumption is cut by about 80% when in standby.
Night set mode
Saves energy by preventing overcooling or overheating during night time.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling.
Comfort mode
Guarantees draught-free operation by preventing warm or cold air from being blown directly at people in the room.
POWER mode
Can be selected for rapid heating or cooling; once the desired temperature is reached, the unit returns to its original setting.
Auto cooling-heating changeover
Automatically selects heating or cooling mode to achieve the set temperature.
Quiet operation of the indoor unit
"Silent" buttons on the remote control reduce the indoor unit's operating sound by 3dB(A)
Extra quiet outdoor unit function
The "Silent" button on the remote control reduces the outdoor unit's operating sound by 3dB(A) to avoid disturbing the neighbourhood.
3-D air flow
Combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
Vertical auto swing
Possibility to select automatic vertical moving of the air discharge louvre, for an efficient air and temperature distribution throughout the room.
Horizontal auto swing
Possibility to select automatic horizontal moving of the air discharge louvre, for an efficient air and temperature distribution throughout the room.
Automatic fan speed
Automatically selects the necessary fan speed to reach or maintain the set temperature.
Fan speed steps (5 steps)
Allows to select up to the given number of fan speed steps.
Dry programme
This function reduces humidity levels without variations in room temperature.
Flash Streamer
Flash Streamer uses electrons to trigger chemical reactions with air-borne particles, breaking down allergens such as pollen and mould and removing bothersome odours to provide better, cleaner air
Titanium apatite deodorising filter
Breaks down bothersome odours such as tobacco and pet smells
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Weekly timer
Can be set to start heating or cooling anytime on a daily or weekly basis.
24-hour timer
Can be set to start heating or cooling anytime during a 24-hour period.
Infrared remote control
Starts, stops and regulates the air conditioner from a distance.
Wired remote control
Starts, stops and regulates the air conditioner.
Central remote control
Starts, stops and regulates several air conditioners from one central point.
Auto-restart
The unit restarts automatically at the original settings after power failure.
Self diagnosis
Simplifies maintenance by indicating system faults or operating anomalies.
Technical Data Table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Medium high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Silent |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Medium high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Silent |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard Accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation Manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Indoor unit fixing screws |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adaptor kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
Depth |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium high |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Silent operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium high |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Silent operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|
Standard accessories |
Silver ion filter |
|
|
|
|
|
|
1 |
1 |
1 |
|||||
VIDEO
https://youtu.be/O0B0xmCuLE4
Specifications
No specifications.
Wall-mounted unit
Perfera - FTXM-R
Attractive wall-mounted unit ensures perfect indoor air quality
Product features
- Seasonal efficiency up to A+++ in cooling and heating mode, thanks to its advanced technology and built-in intelligence.
- Heat boost quickly heats up your home when starting your air conditioner. Set temperature is reached 14% faster than with a normal air conditioner (pair only)
- Flash Streamer uses electrons to trigger chemical reactions with air-borne particles, breaking down allergens such as pollen and mould and removing bothersome odours to provide better, cleaner air
- The silver allergen removal and air purification filter captures allergens such as pollen to ensure a steady supply of clean air
- Daikin Residential Controller: control your indoor unit from any location via app, your local network or the internet.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc.
- Quiet operation: sound pressure level down to 19 dBA
- 3D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
- 2-area motion sensor: air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting. (larger capacity area)
Benefits
Silver allergen removal and air purification filter
Captures allergens such as pollen to ensure a steady supply of clean air
Whisper quiet
Whisper quiet: the unit runs so quietly you'll forget it's even there.
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Heat boost
Quickly heats up your home when starting your air conditioner. Set temperature is reached 20% faster than with a normal air conditioner (pair only)
Onecta App
Control your indoor climate from any location via smartphone or tablet
Econo mode
Decreases power consumption so that other high power consumption appliances can be used. This function is also energy-saving.
2-area motion sensor
Air flow is sent to a zone other than where the person is currently located. If no people are detected, the unit will automatically switch over to energy-efficient setting.
Energy-saving standby mode
Power consumption is cut by about 80% when in standby.
Night set mode
Saves energy by preventing overcooling or overheating during night time.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling.
Comfort mode
Guarantees draught-free operation by preventing warm or cold air from being blown directly at people in the room.
POWER mode
Can be selected for rapid heating or cooling; once the desired temperature is reached, the unit returns to its original setting.
Auto cooling-heating changeover
Automatically selects heating or cooling mode to achieve the set temperature.
Quiet operation of the indoor unit
"Silent" buttons on the remote control reduce the indoor unit's operating sound by 3dB(A)
Extra quiet outdoor unit function
The "Silent" button on the remote control reduces the outdoor unit's operating sound by 3dB(A) to avoid disturbing the neighbourhood.
3-D air flow
Combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
Vertical auto swing
Possibility to select automatic vertical moving of the air discharge louvre, for an efficient air and temperature distribution throughout the room.
Horizontal auto swing
Possibility to select automatic horizontal moving of the air discharge louvre, for an efficient air and temperature distribution throughout the room.
Automatic fan speed
Automatically selects the necessary fan speed to reach or maintain the set temperature.
Fan speed steps (5 steps)
Allows to select up to the given number of fan speed steps.
Dry programme
This function reduces humidity levels without variations in room temperature.
Flash Streamer
Flash Streamer uses electrons to trigger chemical reactions with air-borne particles, breaking down allergens such as pollen and mould and removing bothersome odours to provide better, cleaner air
Titanium apatite deodorising filter
Breaks down bothersome odours such as tobacco and pet smells
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Weekly timer
Can be set to start heating or cooling anytime on a daily or weekly basis.
24-hour timer
Can be set to start heating or cooling anytime during a 24-hour period.
Infrared remote control
Starts, stops and regulates the air conditioner from a distance.
Wired remote control
Starts, stops and regulates the air conditioner.
Central remote control
Starts, stops and regulates several air conditioners from one central point.
Auto-restart
The unit restarts automatically at the original settings after power failure.
Self diagnosis
Simplifies maintenance by indicating system faults or operating anomalies.
Technical Data Table for FTXM-R
|
FTXM20R2V1B |
FTXM20R5V1B |
FTXM25R2V1B |
FTXM25R5V1B |
FTXM35R2V1B |
FTXM35R5V1B |
FTXM50R2V1B |
FTXM60R2V1B |
FTXM71R2V1B |
FTXM42R2V1B (Archived) |
FTXM42R5V1B (Archived) |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
39 |
39 |
39 |
39 |
39 |
43 |
45 |
46 |
45 |
45 |
|
|
|
|
Medium high |
dB(A) |
34 |
34 |
34 |
34 |
35 |
35 |
39 |
41 |
42 |
39 |
39 |
|
|
|
|
Silent |
dB(A) |
20 |
20 |
20 |
20 |
20 |
20 |
31 |
33 |
34 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
28 |
28 |
34 |
36 |
37 |
29 |
29 |
|
|
|
Cooling |
Medium high |
dB(A) |
33 |
33 |
33 |
33 |
33 |
33 |
40 |
42 |
43 |
39 |
39 |
|
|
|
|
Silent |
dB(A) |
19 |
19 |
19 |
19 |
19 |
19 |
27 |
30 |
32 |
21 |
21 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
25 |
29 |
29 |
36 |
37 |
38 |
30 |
30 |
|
|
|
|
High |
dB(A) |
41 |
41 |
41 |
41 |
45 |
45 |
44 |
46 |
47 |
45 |
45 |
|
|
Standard Accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation Manual |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
1 |
1 |
|||
|
|
Indoor unit fixing screws |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
W-LAN adaptor kit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
Wired remote controller |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote controller |
|
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
ARC466A67 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
15.9 |
9.50 |
9.50 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.029 |
0.029 |
0.025 |
0.025 |
0.030 |
0.030 |
0.030 |
0.032 |
0.054 |
0.034 |
0.034 |
|
|
|
Heating |
Nom. |
kW |
0.023 |
0.023 |
0.022 |
0.022 |
0.027 |
0.027 |
0.032 |
0.035 |
0.060 |
0.038 |
0.038 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
57 |
57 |
58 |
58 |
58 |
60 |
60 |
60 |
60 |
||
|
|
Heating |
dB(A) |
54 |
54 |
54 |
54 |
54 |
54 |
58 |
59 |
61 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
778 |
778 |
778 |
778 |
778 |
778 |
998 |
998 |
998 |
778 |
778 |
|
|
|
|
Depth |
mm |
272 |
272 |
272 |
272 |
272 |
272 |
292 |
292 |
292 |
272 |
272 |
|
|
|
|
Height |
mm |
295 |
295 |
295 |
295 |
295 |
295 |
299 |
299 |
299 |
295 |
295 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
10.0 |
14.5 |
14.5 |
14.5 |
10.0 |
10.0 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
9.3 |
9.3 |
9.8 |
9.8 |
9.8 |
9.8 |
15.8 |
16.5 |
17.7 |
12.4 |
12.4 |
|
|
|
|
Medium high |
m³/min |
8.2 |
8.2 |
8.0 |
8.0 |
8.5 |
8.5 |
14.2 |
15.2 |
15.8 |
9.7 |
9.7 |
|
|
|
|
Low |
m³/min |
6.2 |
6.2 |
6.3 |
6.3 |
6.5 |
6.5 |
12.0 |
12.4 |
12.7 |
6.5 |
6.5 |
|
|
|
|
Silent operation |
m³/min |
5.1 |
5.1 |
4.9 |
4.9 |
4.9 |
4.9 |
10.5 |
11.1 |
11.6 |
4.9 |
4.9 |
|
|
|
Cooling |
Low |
m³/min |
5.7 |
5.7 |
5.7 |
5.7 |
6.0 |
6.0 |
11.4 |
11.8 |
12.2 |
6.5 |
6.5 |
|
|
|
|
Medium high |
m³/min |
7.5 |
7.5 |
7.6 |
7.6 |
7.8 |
7.8 |
14.0 |
14.0 |
15.0 |
9.0 |
9.0 |
|
|
|
|
High |
m³/min |
10.5 |
10.5 |
10.5 |
10.5 |
11.3 |
11.3 |
15.8 |
16.7 |
16.9 |
11.9 |
11.9 |
|
|
|
|
Silent operation |
m³/min |
4.3 |
4.3 |
4.1 |
4.1 |
4.2 |
4.2 |
8.3 |
9.1 |
10.0 |
4.3 |
4.3 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
|
Standard accessories |
Silver ion filter |
|
|
|
|
|
|
1 |
1 |
1 |
|||||
VIDEO
https://youtu.be/O0B0xmCuLE4
No specifications.