











DAIKIN EMURA FTXJ-3.5KW SILVER (A+++/A+++)

Product Information
Product information
Daikin Emura - FTXJ-
Design that speaks for itself
Product features
- A remarkable blend of iconic design and cutting-edge technology with an elegant matte white finish.
- The Coanda effect optimises airflow for a comfortable indoor climate. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
- The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the space. It then switches to an airflow pattern that directs warm and cool air to the right place.
- Heat boost quickly warms up your home after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (for some models only).
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould, and removing bothersome odours to deliver better, purer air.
- Voice control via Amazon Alexa or Google Assistant to control key functions such as setpoint, operating mode, fan speed, etc.
- Daikin Residential Controller: control your indoor unit from any location via an app, through your local network or the internet.
- Whisper-quiet operation: the system's operation is barely audible. The sound pressure level is only 19 dB(A)!
Benefits
Coanda effect: cooling
The Coanda effect optimises airflow in cooling mode. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
Coanda effect: heating
The Coanda effect optimises airflow in heating mode. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
Onecta via app
Control your indoor unit from any location via an app
Multi-split compatible
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Intelligent thermal sensor
The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the space. It then switches to an airflow pattern that directs warm and cool air to the right place.
Econo mode
Reduces power consumption, allowing other high-power-consumption systems to be used. This function is also energy-saving.
Energy-saving standby mode
In standby, power consumption drops by approximately 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling it.
Comfort mode
Ensures that cold drafts are minimised by preventing warm or cool air from being directed straight at occupants.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit reverts to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Whisper-quiet indoor unit operation
"Silent" buttons on the remote control reduce the indoor unit's operating sound by 3dB(A)
3-D airflow
Combines vertical and horizontal auto-swing to ensure the warm or cool airflow reaches every corner, even in large spaces.
Vertical auto-swing
Ability to automatically move the discharge flaps vertically for even airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge louvre horizontally for even airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to reach or maintain the set temperature.
Fan speeds
All specified fan speeds are selectable with a single button.
Dry program
This function reduces humidity without variations in room temperature.
Silver filter for allergen control and air purification
Removes allergens such as pollen to ensure a constant supply of clean air
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould, and removing bothersome odours to deliver better, purer air.
Titanium apatite deodorising filter
Decomposes bothersome odours from, for example, tobacco and pets.
Heat boost
Quickly warms your home after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (for some models only).
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The heating or cooling timer can be set for any time of day or weekly.
Automatic restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operational malfunctions.
Technical data table for FTXJ-AW
|
FTXJ20A2V1BW |
FTXJ25A2V1BW |
FTXJ35A2V1BW |
FTXJ42A2V1BW |
FTXJ50A2V1BW |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
|
|
Medium-high |
dB(A) |
32 |
33 |
33 |
37 |
42 |
|
|
|
|
Whisper quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
33 |
|
|
|
Cooling |
Medium-high |
dB(A) |
32 |
33 |
33 |
37 |
39 |
|
|
|
|
Whisper quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
31 |
|
|
|
|
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Silver particle filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Screw cover |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Screw bag |
1 |
1 |
1 |
1 |
1 |
|||
|
|
General precautions |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
|||
|
Refrigerant |
GWP |
|
675 |
675 |
675 |
675 |
675 |
||
|
Control systems |
Wired remote control |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote control |
|
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
||
|
Pipe connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
||
|
Power consumption |
Cooling |
Nom. |
kW |
0.020 |
0.022 |
0.024 |
0.028 |
0.031 |
|
|
|
Heating |
Nom. |
kW |
0.021 |
0.022 |
0.024 |
0.036 |
0.039 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
60 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
900 |
900 |
900 |
900 |
900 |
|
|
|
|
D |
mm |
212 |
212 |
212 |
212 |
212 |
|
|
|
|
Height |
mm |
305 |
305 |
305 |
305 |
305 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
12 |
12 |
12 |
12 |
12 |
||
|
Fan |
Air flow rate |
Heating |
High |
m³/min |
11.1 |
11.3 |
11.7 |
14.4 |
15.0 |
|
|
|
|
Medium-high |
m³/min |
8.7 |
9.0 |
9.0 |
10.5 |
11.1 |
|
|
|
|
Low |
m³/min |
6.4 |
6.4 |
6.4 |
7.7 |
8.2 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
5.2 |
5.7 |
|
|
|
Cooling |
Low |
m³/min |
6.0 |
6.0 |
6.0 |
7.2 |
7.6 |
|
|
|
|
Medium-high |
m³/min |
8.4 |
8.6 |
8.6 |
9.5 |
10.4 |
|
|
|
|
High |
m³/min |
11.0 |
11.4 |
11.8 |
13.0 |
13.5 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
4.6 |
5.2 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
VIDEO
Specifications
No specifications.
Daikin Emura - FTXJ-
Design that speaks for itself
Product features
- A remarkable blend of iconic design and cutting-edge technology with an elegant matte white finish.
- The Coanda effect optimises airflow for a comfortable indoor climate. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
- The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the space. It then switches to an airflow pattern that directs warm and cool air to the right place.
- Heat boost quickly warms up your home after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (for some models only).
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould, and removing bothersome odours to deliver better, purer air.
- Voice control via Amazon Alexa or Google Assistant to control key functions such as setpoint, operating mode, fan speed, etc.
- Daikin Residential Controller: control your indoor unit from any location via an app, through your local network or the internet.
- Whisper-quiet operation: the system's operation is barely audible. The sound pressure level is only 19 dB(A)!
Benefits
Coanda effect: cooling
The Coanda effect optimises airflow in cooling mode. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
Coanda effect: heating
The Coanda effect optimises airflow in heating mode. Thanks to specially designed flaps, the directed airflow ensures better air distribution throughout the room.
Onecta via app
Control your indoor unit from any location via an app
Multi-split compatible
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Intelligent thermal sensor
The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the space. It then switches to an airflow pattern that directs warm and cool air to the right place.
Econo mode
Reduces power consumption, allowing other high-power-consumption systems to be used. This function is also energy-saving.
Energy-saving standby mode
In standby, power consumption drops by approximately 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling it.
Comfort mode
Ensures that cold drafts are minimised by preventing warm or cool air from being directed straight at occupants.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit reverts to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Whisper-quiet indoor unit operation
"Silent" buttons on the remote control reduce the indoor unit's operating sound by 3dB(A)
3-D airflow
Combines vertical and horizontal auto-swing to ensure the warm or cool airflow reaches every corner, even in large spaces.
Vertical auto-swing
Ability to automatically move the discharge flaps vertically for even airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge louvre horizontally for even airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to reach or maintain the set temperature.
Fan speeds
All specified fan speeds are selectable with a single button.
Dry program
This function reduces humidity without variations in room temperature.
Silver filter for allergen control and air purification
Removes allergens such as pollen to ensure a constant supply of clean air
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles, breaking down allergens such as pollen and mould, and removing bothersome odours to deliver better, purer air.
Titanium apatite deodorising filter
Decomposes bothersome odours from, for example, tobacco and pets.
Heat boost
Quickly warms your home after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (for some models only).
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The heating or cooling timer can be set for any time of day or weekly.
Automatic restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operational malfunctions.
Technical data table for FTXJ-AW
|
FTXJ20A2V1BW |
FTXJ25A2V1BW |
FTXJ35A2V1BW |
FTXJ42A2V1BW |
FTXJ50A2V1BW |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
|
|
Medium-high |
dB(A) |
32 |
33 |
33 |
37 |
42 |
|
|
|
|
Whisper quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
33 |
|
|
|
Cooling |
Medium-high |
dB(A) |
32 |
33 |
33 |
37 |
39 |
|
|
|
|
Whisper quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
31 |
|
|
|
|
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Silver particle filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Screw cover |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Screw bag |
1 |
1 |
1 |
1 |
1 |
|||
|
|
General precautions |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
|||
|
Refrigerant |
GWP |
|
675 |
675 |
675 |
675 |
675 |
||
|
Control systems |
Wired remote control |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote control |
|
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
||
|
Pipe connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
||
|
Power consumption |
Cooling |
Nom. |
kW |
0.020 |
0.022 |
0.024 |
0.028 |
0.031 |
|
|
|
Heating |
Nom. |
kW |
0.021 |
0.022 |
0.024 |
0.036 |
0.039 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
60 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
900 |
900 |
900 |
900 |
900 |
|
|
|
|
D |
mm |
212 |
212 |
212 |
212 |
212 |
|
|
|
|
Height |
mm |
305 |
305 |
305 |
305 |
305 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
12 |
12 |
12 |
12 |
12 |
||
|
Fan |
Air flow rate |
Heating |
High |
m³/min |
11.1 |
11.3 |
11.7 |
14.4 |
15.0 |
|
|
|
|
Medium-high |
m³/min |
8.7 |
9.0 |
9.0 |
10.5 |
11.1 |
|
|
|
|
Low |
m³/min |
6.4 |
6.4 |
6.4 |
7.7 |
8.2 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
5.2 |
5.7 |
|
|
|
Cooling |
Low |
m³/min |
6.0 |
6.0 |
6.0 |
7.2 |
7.6 |
|
|
|
|
Medium-high |
m³/min |
8.4 |
8.6 |
8.6 |
9.5 |
10.4 |
|
|
|
|
High |
m³/min |
11.0 |
11.4 |
11.8 |
13.0 |
13.5 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
4.6 |
5.2 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
VIDEO
No specifications.