




















DAIKIN EMURA FTXJ-AW 2.5KW WHITE (A+++/A+++)

Product Information
Product information
Daikin Emura - FTXJ-
Design that speaks for itself
Product features
- A remarkable blend of iconic design and cutting-edge technology with an elegant matte white finish.
- The Coanda effect optimises airflow for a comfortable indoor climate. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
- The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the room. It then switches to an airflow pattern that directs warm and cool air to the right place.
- Heat boost quickly warms up your home after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (only with some models)
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles to break down allergens such as pollen and mould and remove unpleasant odours to deliver better, purer air.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operating mode, fan speed, etc.
- Daikin Residential Controller: control your indoor unit from anywhere with an app, via your local network or the internet.
- Whisper-quiet operation: the system's operation is barely audible. The sound pressure level is only 19 dB(A)!
Benefits
Coanda effect: cooling
The Coanda effect optimises airflow in cooling mode. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
Coanda effect: heating
The Coanda effect optimises airflow in heating mode. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
Onecta via app
Control your indoor unit from any location via an app
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled independently within the same mode (heating or cooling).
Intelligent thermal sensor
The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the room. It then switches to an airflow pattern that directs warm and cool air to the right place.
Econo mode
Reduces power consumption, allowing other high-power consumption systems to be used. This function is also energy-saving.
Energy-saving standby mode
In standby, power consumption drops by about 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling it.
Comfort mode
Ensures that cold draughts are minimised by preventing warm or cool air from being directed directly at people present.
POWER mode
Selectable for quick heating or cooling; once the desired temperature is reached, the unit switches back to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Whisper-quiet indoor unit operation
"Silent" buttons on the remote control reduce the indoor unit's operating noise by 3dB(A)
3-D airflow
Combines vertical and horizontal auto-swing to ensure that the warm or cool airflow reaches even the furthest corners in large rooms.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically for uniform airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge blade horizontally, creating uniform airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to reach or maintain the set temperature.
Fan speeds
All specified fan speeds are selectable with a single button.
Dry programme
This function reduces humidity without variations in room temperature.
Silver filter for allergen control and air purification
Removes allergens such as pollen to ensure a constant supply of clean air
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles to break down allergens such as pollen and mould and remove unpleasant odours to deliver better, purer air.
Titanium apatite deodorising filter
Decomposes unpleasant odours from tobacco and pets, for example
Heat boost
Warms your home quickly after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (only with some models)
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The heating or cooling timer can be set for any desired time of day or weekly.
Automatic restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system failures or operational faults.
Technical data table for FTXJ-AW
|
FTXJ20A2V1BW |
FTXJ25A2V1BW |
FTXJ35A2V1BW |
FTXJ42A2V1BW |
FTXJ50A2V1BW |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
|
|
Medium |
dB(A) |
32 |
33 |
33 |
37 |
42 |
|
|
|
|
Whisper-quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
33 |
|
|
|
Cooling |
Medium |
dB(A) |
32 |
33 |
33 |
37 |
39 |
|
|
|
|
Whisper-quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
31 |
|
|
|
|
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operating manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry-cell battery |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Silver particle filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Screw cap |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Bag of screws |
1 |
1 |
1 |
1 |
1 |
|||
|
|
General precautions |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
|||
|
Refrigerant |
GWP |
|
675 |
675 |
675 |
675 |
675 |
||
|
Control systems |
Wired remote control |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote control |
|
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
||
|
Pipe connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.020 |
0.022 |
0.024 |
0.028 |
0.031 |
|
|
|
Heating |
Nom. |
kW |
0.021 |
0.022 |
0.024 |
0.036 |
0.039 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
60 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
900 |
900 |
900 |
900 |
900 |
|
|
|
|
D |
mm |
212 |
212 |
212 |
212 |
212 |
|
|
|
|
Height |
mm |
305 |
305 |
305 |
305 |
305 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
12 |
12 |
12 |
12 |
12 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
11.1 |
11.3 |
11.7 |
14.4 |
15.0 |
|
|
|
|
Medium |
m³/min |
8.7 |
9.0 |
9.0 |
10.5 |
11.1 |
|
|
|
|
Low |
m³/min |
6.4 |
6.4 |
6.4 |
7.7 |
8.2 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
5.2 |
5.7 |
|
|
|
Cooling |
Low |
m³/min |
6.0 |
6.0 |
6.0 |
7.2 |
7.6 |
|
|
|
|
Medium |
m³/min |
8.4 |
8.6 |
8.6 |
9.5 |
10.4 |
|
|
|
|
High |
m³/min |
11.0 |
11.4 |
11.8 |
13.0 |
13.5 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
4.6 |
5.2 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
VIDEO
Specifications
No specifications.
Daikin Emura - FTXJ-
Design that speaks for itself
Product features
- A remarkable blend of iconic design and cutting-edge technology with an elegant matte white finish.
- The Coanda effect optimises airflow for a comfortable indoor climate. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
- The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the room. It then switches to an airflow pattern that directs warm and cool air to the right place.
- Heat boost quickly warms up your home after starting your air conditioner. The set temperature is reached 14% faster than with a normal air conditioner (only with some models)
- The Flash Streamer uses electrons to trigger chemical reactions with airborne particles to break down allergens such as pollen and mould and remove unpleasant odours to deliver better, purer air.
- Voice control via Amazon Alexa or Google Assistant to control main functions such as set point, operating mode, fan speed, etc.
- Daikin Residential Controller: control your indoor unit from anywhere with an app, via your local network or the internet.
- Whisper-quiet operation: the system's operation is barely audible. The sound pressure level is only 19 dB(A)!
Benefits
Coanda effect: cooling
The Coanda effect optimises airflow in cooling mode. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
Coanda effect: heating
The Coanda effect optimises airflow in heating mode. Thanks to specially designed flaps, the targeted airflow ensures better air distribution throughout the room.
Onecta via app
Control your indoor unit from any location via an app
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled independently within the same mode (heating or cooling).
Intelligent thermal sensor
The intelligent thermal sensor determines the current room temperature and then distributes air evenly throughout the room. It then switches to an airflow pattern that directs warm and cool air to the right place.
Econo mode
Reduces power consumption, allowing other high-power consumption systems to be used. This function is also energy-saving.
Energy-saving standby mode
In standby, power consumption drops by about 80%.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only
The unit can be used as a fan, circulating air in the room without heating or cooling it.
Comfort mode
Ensures that cold draughts are minimised by preventing warm or cool air from being directed directly at people present.
POWER mode
Selectable for quick heating or cooling; once the desired temperature is reached, the unit switches back to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Whisper-quiet indoor unit operation
"Silent" buttons on the remote control reduce the indoor unit's operating noise by 3dB(A)
3-D airflow
Combines vertical and horizontal auto-swing to ensure that the warm or cool airflow reaches even the furthest corners in large rooms.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically for uniform airflow and temperature distribution in the room.
Horizontal auto-swing
Ability to automatically move the discharge blade horizontally, creating uniform airflow and temperature distribution.
Automatic fan speed
Automatically selects the appropriate fan speed to reach or maintain the set temperature.
Fan speeds
All specified fan speeds are selectable with a single button.
Dry programme
This function reduces humidity without variations in room temperature.
Silver filter for allergen control and air purification
Removes allergens such as pollen to ensure a constant supply of clean air
Flash Streamer
The Flash Streamer uses electrons to trigger chemical reactions with airborne particles to break down allergens such as pollen and mould and remove unpleasant odours to deliver better, purer air.
Titanium apatite deodorising filter
Decomposes unpleasant odours from tobacco and pets, for example
Heat boost
Warms your home quickly after starting your air conditioner. The set temperature is reached 20% faster than with a normal air conditioner (only with some models)
Air filter
Captures the smallest dust particles to ensure a constant supply of clean air.
Weekly timer
The heating or cooling timer can be set for any desired time of day or weekly.
Automatic restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system failures or operational faults.
Technical data table for FTXJ-AW
|
FTXJ20A2V1BW |
FTXJ25A2V1BW |
FTXJ35A2V1BW |
FTXJ42A2V1BW |
FTXJ50A2V1BW |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
|
|
Medium |
dB(A) |
32 |
33 |
33 |
37 |
42 |
|
|
|
|
Whisper-quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
33 |
|
|
|
Cooling |
Medium |
dB(A) |
32 |
33 |
33 |
37 |
39 |
|
|
|
|
Whisper-quiet operation |
dB(A) |
19 |
19 |
19 |
21 |
24 |
|
|
|
|
Low |
dB(A) |
25 |
25 |
25 |
29 |
31 |
|
|
|
|
High |
dB(A) |
39 |
40 |
41 |
45 |
46 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operating manual |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry-cell battery |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Silver particle filter |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Screw cap |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Bag of screws |
1 |
1 |
1 |
1 |
1 |
|||
|
|
General precautions |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
|||
|
Refrigerant |
GWP |
|
675 |
675 |
675 |
675 |
675 |
||
|
Control systems |
Wired remote control |
|
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
BRC073A1 |
||
|
|
IR remote control |
|
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
ARC488A1W |
||
|
Pipe connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.50 |
9.50 |
9.50 |
12.7 |
12.7 |
||
|
|
Drain |
|
18 |
18 |
18 |
18 |
18 |
||
|
Power input |
Cooling |
Nom. |
kW |
0.020 |
0.022 |
0.024 |
0.028 |
0.031 |
|
|
|
Heating |
Nom. |
kW |
0.021 |
0.022 |
0.024 |
0.036 |
0.039 |
|
|
Sound power level |
Cooling |
dB(A) |
57 |
57 |
60 |
60 |
60 |
||
|
Dimensions |
Unit |
Width |
mm |
900 |
900 |
900 |
900 |
900 |
|
|
|
|
D |
mm |
212 |
212 |
212 |
212 |
212 |
|
|
|
|
Height |
mm |
305 |
305 |
305 |
305 |
305 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
12 |
12 |
12 |
12 |
12 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
11.1 |
11.3 |
11.7 |
14.4 |
15.0 |
|
|
|
|
Medium |
m³/min |
8.7 |
9.0 |
9.0 |
10.5 |
11.1 |
|
|
|
|
Low |
m³/min |
6.4 |
6.4 |
6.4 |
7.7 |
8.2 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
5.2 |
5.7 |
|
|
|
Cooling |
Low |
m³/min |
6.0 |
6.0 |
6.0 |
7.2 |
7.6 |
|
|
|
|
Medium |
m³/min |
8.4 |
8.6 |
8.6 |
9.5 |
10.4 |
|
|
|
|
High |
m³/min |
11.0 |
11.4 |
11.8 |
13.0 |
13.5 |
|
|
|
|
Quiet operation |
m³/min |
4.6 |
4.6 |
4.6 |
4.6 |
5.2 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Name |
|
V1 |
V1 |
V1 |
V1 |
V1 |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-240 |
220-240 |
220-240 |
220-240 |
220-240 |
||
|
Remarks |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
(1) - Cooling: indoor temp. 27°CDB, 19.0°CNB, outdoor temp. 35°CDB, 24°CWB; equivalent pipe length: 5m |
||||
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB/6°CWB; equivalent refrigerant pipe length: 5m |
||||
VIDEO
No specifications.