





DAIKIN CONSOLE WHITE 3.5KW (A++/A+)

Product Information
Product information
Floor standing unit
FVXM-F
Floor standing unit for optimum heating comfort thanks to dual airflow
Product features
- Its limited height (620 mm) allows the floor standing unit to fit perfectly under a window
- Daikin Residential Controller (optional): control your indoor unit from any location with an app, via your local network or the internet.
- Quiet operation: sound pressure level down to 23 dBA
- Opt for an R-32 product to reduce your environmental impact by 68% compared to R-410A systems and directly reduce your energy consumption, thanks to its high energy efficiency.
- Voice control via Amazon Alexa or Google Assistant to control the main functions, such as setpoint, operating mode, fan speed, etc.
Benefits
Onecta App (optional)
Control your indoor climate anywhere via a smartphone or tablet
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Econo mode
Reduces energy consumption, allowing other systems with high energy consumption to be used. This function is also energy-saving.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only mode
The unit can be used as a fan, circulating air in the room without heating or cooling it.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Indoor unit quiet operation
"Silent" buttons on the remote control reduce the operating noise of the indoor unit by 3dB(A)
Outdoor unit extra quiet function
The "Silent" button on the remote control reduces the operating noise of the outdoor unit by 3dB(A) to avoid disturbing the neighbours.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically, for an even airflow and temperature distribution in the room.
Automatic fan speed
Automatically selects the appropriate fan speed to achieve or maintain the set temperature.
Fan speeds
All specified fan speeds can be selected with a single button.
Dry programme
This function reduces humidity without variations in room temperature.
Titanium apatite deodorising filter
Breaks down unpleasant odours, for example, from tobacco and pets
Weekly timer
The timer for heating or cooling can be set for any desired time of day or weekly.
24-hour timer
Programmable to start heating or cooling at a specific time within a 24-hour period.
Infrared remote control
Starts, stops and controls the air conditioner remotely.
Centralised remote control
For remote starting, stopping and controlling multiple air conditioners from a central point.
Auto-restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operating failures.
Technical data table for FVXM-F
|
FVXM25FV1B |
FVXM25FV1B9 |
FVXM35FV1B |
FVXM35FV1B9 |
FVXM50FV1B |
FVXM50FV1B9 |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
38 |
38 |
39 |
39 |
45 |
45 |
|
|
|
|
Medium |
dB(A) |
32 |
32 |
33 |
33 |
40 |
40 |
|
|
|
|
Quiet operation |
dB(A) |
23 |
23 |
24 |
24 |
32 |
32 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
36 |
36 |
|
|
|
Cooling |
Medium |
dB(A) |
32 |
32 |
33 |
33 |
40 |
40 |
|
|
|
|
Quiet operation |
dB(A) |
23 |
23 |
24 |
24 |
32 |
32 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
36 |
36 |
|
|
|
|
High |
dB(A) |
38 |
38 |
39 |
39 |
44 |
44 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Drain hose |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Insulation plate |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
IR remote control |
|
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.5 |
9.5 |
9.5 |
9.5 |
12.7 |
12.7 |
||
|
|
Drain |
|
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
||
|
Power input |
Cooling |
Nom. |
kW |
0.015 (1) |
0.015 (1) |
0.015 (1) |
0.015 (1) |
0.027 (1) |
0.027 (1) |
|
|
|
Heating |
Nom. |
kW |
0.017 (1) |
0.017 (1) |
0.017 (1) |
0.017 (1) |
0.034 (1) |
0.034 (1) |
|
|
Sound power level |
Cooling |
dB(A) |
52 |
52 |
52 |
52 |
57 |
57 |
||
|
|
Heating |
dB(A) |
52 |
52 |
52 |
52 |
58 |
58 |
||
|
Dimensions |
Unit |
Width |
mm |
700 |
700 |
700 |
700 |
700 |
700 |
|
|
|
|
D |
mm |
210 |
210 |
210 |
210 |
210 |
210 |
|
|
|
|
Height |
mm |
600 |
600 |
600 |
600 |
600 |
600 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
14 |
14 |
14 |
14 |
14 |
14 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
8.8 |
8.8 |
9.4 |
9.4 |
11.8 |
11.8 |
|
|
|
|
Medium-High |
m³/min |
6.9 |
6.9 |
7.3 |
7.3 |
10.1 |
10.1 |
|
|
|
|
Low |
m³/min |
5.0 |
5.0 |
5.2 |
5.2 |
8.5 |
8.5 |
|
|
|
|
Quiet operation |
m³/min |
4.4 |
4.4 |
4.7 |
4.7 |
7.1 |
7.1 |
|
|
|
Cooling |
Low |
m³/min |
4.8 |
4.8 |
4.9 |
4.9 |
7.8 |
7.8 |
|
|
|
|
Medium-High |
m³/min |
6.5 |
6.5 |
6.7 |
6.7 |
8.9 |
8.9 |
|
|
|
|
High |
m³/min |
8.2 |
8.2 |
8.5 |
8.5 |
10.1 |
10.1 |
|
|
|
|
Quiet operation |
m³/min |
4.1 |
4.1 |
4.5 |
4.5 |
6.6 |
6.6 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
||
|
Remarks |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
||||
|
|
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
||||
|
|
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
||||
|
|
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
||||
Specifications
No specifications.
Floor standing unit
FVXM-F
Floor standing unit for optimum heating comfort thanks to dual airflow
Product features
- Its limited height (620 mm) allows the floor standing unit to fit perfectly under a window
- Daikin Residential Controller (optional): control your indoor unit from any location with an app, via your local network or the internet.
- Quiet operation: sound pressure level down to 23 dBA
- Opt for an R-32 product to reduce your environmental impact by 68% compared to R-410A systems and directly reduce your energy consumption, thanks to its high energy efficiency.
- Voice control via Amazon Alexa or Google Assistant to control the main functions, such as setpoint, operating mode, fan speed, etc.
Benefits
Onecta App (optional)
Control your indoor climate anywhere via a smartphone or tablet
Suitable for multi-split
Up to 5 indoor units, even with different capacities, can be connected to a single outdoor unit. All indoor units can be controlled individually within the same mode (heating or cooling).
Econo mode
Reduces energy consumption, allowing other systems with high energy consumption to be used. This function is also energy-saving.
Night mode
Saves energy by preventing excessive cooling or heating during the night.
Fan only mode
The unit can be used as a fan, circulating air in the room without heating or cooling it.
POWER mode
Selectable for rapid heating or cooling; once the desired temperature is reached, the unit switches back to its original setting.
Automatic cooling/heating changeover
Automatically switches between heating and cooling to achieve the preset temperature.
Indoor unit quiet operation
"Silent" buttons on the remote control reduce the operating noise of the indoor unit by 3dB(A)
Outdoor unit extra quiet function
The "Silent" button on the remote control reduces the operating noise of the outdoor unit by 3dB(A) to avoid disturbing the neighbours.
Vertical auto-swing
Ability to automatically move the discharge louvres vertically, for an even airflow and temperature distribution in the room.
Automatic fan speed
Automatically selects the appropriate fan speed to achieve or maintain the set temperature.
Fan speeds
All specified fan speeds can be selected with a single button.
Dry programme
This function reduces humidity without variations in room temperature.
Titanium apatite deodorising filter
Breaks down unpleasant odours, for example, from tobacco and pets
Weekly timer
The timer for heating or cooling can be set for any desired time of day or weekly.
24-hour timer
Programmable to start heating or cooling at a specific time within a 24-hour period.
Infrared remote control
Starts, stops and controls the air conditioner remotely.
Centralised remote control
For remote starting, stopping and controlling multiple air conditioners from a central point.
Auto-restart
After a power failure, the indoor unit automatically restarts with the original settings.
Fault diagnosis
Simplifies maintenance by indicating system faults or operating failures.
Technical data table for FVXM-F
|
FVXM25FV1B |
FVXM25FV1B9 |
FVXM35FV1B |
FVXM35FV1B9 |
FVXM50FV1B |
FVXM50FV1B9 |
|||||
|
Sound pressure level at 1 m |
Heating |
High |
dB(A) |
38 |
38 |
39 |
39 |
45 |
45 |
|
|
|
|
Medium |
dB(A) |
32 |
32 |
33 |
33 |
40 |
40 |
|
|
|
|
Quiet operation |
dB(A) |
23 |
23 |
24 |
24 |
32 |
32 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
36 |
36 |
|
|
|
Cooling |
Medium |
dB(A) |
32 |
32 |
33 |
33 |
40 |
40 |
|
|
|
|
Quiet operation |
dB(A) |
23 |
23 |
24 |
24 |
32 |
32 |
|
|
|
|
Low |
dB(A) |
26 |
26 |
27 |
27 |
36 |
36 |
|
|
|
|
High |
dB(A) |
38 |
38 |
39 |
39 |
44 |
44 |
|
|
Standard accessories |
Installation manual |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Operation manual |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Wireless remote control |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
AAA dry cell battery |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Remote control holder |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Drain hose |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
|
Insulation plate |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Titanium apatite deodorising filter |
2 |
2 |
2 |
2 |
2 |
2 |
|||
|
|
Mounting plate |
1 |
1 |
1 |
1 |
1 |
1 |
|||
|
Control systems |
IR remote control |
|
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
ARC452A1 |
||
|
Piping connections |
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
6.35 |
|
|
|
Gas |
mm |
9.5 |
9.5 |
9.5 |
9.5 |
12.7 |
12.7 |
||
|
|
Drain |
|
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
VP20 (I.D. 20/O.D. 26) |
||
|
Power input |
Cooling |
Nom. |
kW |
0.015 (1) |
0.015 (1) |
0.015 (1) |
0.015 (1) |
0.027 (1) |
0.027 (1) |
|
|
|
Heating |
Nom. |
kW |
0.017 (1) |
0.017 (1) |
0.017 (1) |
0.017 (1) |
0.034 (1) |
0.034 (1) |
|
|
Sound power level |
Cooling |
dB(A) |
52 |
52 |
52 |
52 |
57 |
57 |
||
|
|
Heating |
dB(A) |
52 |
52 |
52 |
52 |
58 |
58 |
||
|
Dimensions |
Unit |
Width |
mm |
700 |
700 |
700 |
700 |
700 |
700 |
|
|
|
|
D |
mm |
210 |
210 |
210 |
210 |
210 |
210 |
|
|
|
|
Height |
mm |
600 |
600 |
600 |
600 |
600 |
600 |
|
|
Casing |
Colour |
|
White |
White |
White |
White |
White |
White |
||
|
Weight |
Unit |
kg |
14 |
14 |
14 |
14 |
14 |
14 |
||
|
Fan |
Airflow rate |
Heating |
High |
m³/min |
8.8 |
8.8 |
9.4 |
9.4 |
11.8 |
11.8 |
|
|
|
|
Medium-High |
m³/min |
6.9 |
6.9 |
7.3 |
7.3 |
10.1 |
10.1 |
|
|
|
|
Low |
m³/min |
5.0 |
5.0 |
5.2 |
5.2 |
8.5 |
8.5 |
|
|
|
|
Quiet operation |
m³/min |
4.4 |
4.4 |
4.7 |
4.7 |
7.1 |
7.1 |
|
|
|
Cooling |
Low |
m³/min |
4.8 |
4.8 |
4.9 |
4.9 |
7.8 |
7.8 |
|
|
|
|
Medium-High |
m³/min |
6.5 |
6.5 |
6.7 |
6.7 |
8.9 |
8.9 |
|
|
|
|
High |
m³/min |
8.2 |
8.2 |
8.5 |
8.5 |
10.1 |
10.1 |
|
|
|
|
Quiet operation |
m³/min |
4.1 |
4.1 |
4.5 |
4.5 |
6.6 |
6.6 |
|
Power supply |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
||
|
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
||
|
|
Voltage |
V |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
220-230-240 |
||
|
Remarks |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
(1) - 50 Hz, 220-230-240 V |
||||
|
|
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
(2) - 220V |
||||
|
|
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
(3) - 230V |
||||
|
|
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
(4) - 240V |
||||
No specifications.