AUXPREMIUM-MULTISPLIT-5-KW13 (wifi+frost protector)

Sale price€2.022,00
Re-stocking soon
Split-unit 45,000 BTU: No installation, Pick up at Head Office Tegelen

Split-unit 45,000 BTU


Multisplit Outdoor Unit (incl. WIFI and Frost Protection)

 

Flexible air conditioning solutions for multiple rooms

The multisplit AUX system allows the installation of 2 to 5 indoor units on a single outdoor unit. The range includes 6 outdoor unit models with cooling capacities from 4.1 to 12.0 kW. The devices operate with ecological R32 refrigerant and modern inverter technology, ensuring reliability and energy efficiency. They offer stable operation across a wide range of ambient temperatures, from -15°C to 52°C in cooling mode and from -20°C to 24°C in heating mode. The system allows for the design of cooling systems with a total length of up to 80 meters, depending on the compressor's power, and level differences of up to 15 meters.

 

INTELLIGENT DEFROSTING SYSTEM

Effective operation at low ambient temperatures

The air conditioner activates defrost mode only when necessary and only for the time required to defrost the heat exchanger, allowing the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases heating efficiency by as much as 20% at low ambient temperatures.

 

OUTDOOR UNIT DRIP TRAY HEATER

Efficient operation in heating mode

Outdoor units of the AUX commercial air conditioner series are equipped with drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frost, preventing ice formation on the heat exchanger.

Product Information

Multisplit Unit Outdoor Unit (incl. WIFI and Frost Protector)

 

Flexible air conditioning solutions for multiple rooms

The multisplit AUX system allows the installation of 2 to 5 indoor units to a single outdoor unit. The range includes 6 models of outdoor units with a cooling capacity of 4.1 to 12.0 kW. The units operate with ecological R32 refrigerant and modern inverter technology, ensuring reliability and energy efficiency. They offer stable operation across a wide range of ambient temperatures, from -15°C to 52°C in cooling mode and from -20°C to 24°C in heating mode. The system allows for the design of cooling systems with a total length of up to 80 meters, depending on compressor power and level differences of up to 15 meters.

 

INTELLIGENT DEFROSTING SYSTEM

Effective operation at low ambient temperatures

The air conditioner activates defrost mode only when necessary and only for the time required to defrost the heat exchanger, allowing the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases heating performance by as much as 20% at low ambient temperatures.

 

OUTDOOR UNIT DRIP TRAY HEATER

Efficient operation in heating mode

Outdoor units of the AUX commercial air conditioners series are equipped with drip tray heaters, allowing the devices to operate efficiently in heating mode even in severe frost, preventing ice formation on the heat exchanger.

 

180 SINE WAVE CONTROL

Smooth and efficient compressor operation

The DC inverter compressor uses 180° sine control. This solution ensures the compressor motor runs smoothly and significantly increases efficiency.

 

AUTOMATIC RESTART

Memory settings after power failure

In case of a power failure, the device registers the last settings and restarts after power is restored, automatically resuming the previously set operating mode.

 

HIGH-QUALITY INVERTER COMPRESSOR

Guaranteed energy efficiency and reliability

The inverter rotary compressor of AUX air conditioners guarantees reliable and efficient operation of the devices and the highest energy efficiency parameters. It also ensures low operating costs and low noise levels. Durable and high-quality compressor materials guarantee long and trouble-free operation.

 

R32 REFRIGERANT

Ecological, highly effective, safe

All AUX air conditioning units of the CAC series operate with the latest ecological refrigerant R32, which, compared to the commonly used R41OA refrigerant, is characterized by higher efficiency and a lower greenhouse effect. It also does not deplete the ozone layer.

 

HIGH ENERGY EFFICIENCY

Guarantee of energy-saving operation

Thanks to the use of a highly efficient DC inverter compressor, adjustable fan motor, and advanced 180° sine wave vector control technology, commercial AUX systems achieve high energy efficiency parameters, offering reliable, efficient operation with low energy consumption. All CAC air conditioners are class A++ in cooling mode and A+ in heating mode.

 

A WIDE RANGE from -15 to +52 Degrees

Reliable operation, even in unfavorable weather conditions

AUX commercial air conditioning systems are characterized by reliable, stable operation, even in extreme ambient temperatures. Thanks to the use of modern technologies and high-quality components, AUX devices operate across a wide range of outdoor temperatures, i.e., from -15°C to 52°C in cooling mode and from -20°C to 24°C in heating mode, providing a high level of comfort in the room in all seasons of the year.

 

ANTI-CORROSION CASING OF THE OUTDOOR UNIT

Longer lifespan and better aesthetics

The outdoor unit casing is equipped with a number of protective layers that protect it against insects, rodents, moisture, dust, and fire. It guarantees a long lifespan of the device and better aesthetics after many years of exposure to unfavorable weather conditions.

 

TECHNICAL DATA - OUTDOOR UNITS

Multi split
AUX-M2-(14/18)LCLH, AUX-M3-(21/27)LCLH

Model

 

AUX-M2-14LCLH

AUX-M2-18LCLH

AUX-M3-21LCLH

AUX-M3-27LCLH

Number of indoor units

 

2

2

3

3

Cooling capacity

[kW]

4.1 (1.8-4.51)

5.3 (2.0 - 5.83)

6.2(2.2-6.71)

7.90 (2.3 - 8.69)

[Btu/h]

13989 (6142 -15388)

18084 (6824 -19892)

21154 (7506 - 22895)

26955 (7848 - 29650)

Heating capacity

[kW]

4.8 (2.05 - 5.28)

5.6 (2.21 - 6.16)

6.6 (2.39 - 7.26)

8.20 (2.45 - 9.02)

[Btu/h]

16378 (6995-18015)

19107(7541 -21017)

22519 (8155-24771)

27978 (8359 - 30776)

Power

[V-,Hz,Ph]

220-240, 50,1

220-240, 50,1

220-240, 50,1

220-240, 50,1

Power consumption in cooling mode

[W]

1240 (198-2100)

1750 (280-2300)

1920 (350-2800)

2460 (560 - 3400)

Power consumption in heating mode

[W]

1150 (198-2100)

1540 (280 - 2300)

1780 (350-2800)

2270 (560 - 3400)

Energy consumption (cooling and heating)

[A]

5.4/5

7.6/6.7

8.3 / 7.8

10.7/9.8

Maximum power consumption

[A]

10

11

13

16.0

Energy consumption

[kW]

2.1

2.3

2.8

3.4

SEER /SCOP

[W/W]

6.16/4.06 (F)

7.07/4.08 (F)

6.57/4.38 (F)

6.30/4.04 (F)

6.16/4.06 (J)

7.07 / 4.07(J)

6.57/4.39 (J)

6.30/4.04 (J)

EER / COP

[W/W]

3.31 / 4.17

3.03 / 3.64

3.23 / 3.71

3.21 / 3.61

Energy efficiency class

Cooling

 

A++

A++

A++

A++

Heating

 

A+

A+

A+

A+

Compressor type

 

rotary

rotary

twin rotary

twin rotary

Air flow

[m3/h]

2300

2300

3100

3100

Sound pressure level

[dB(A)]

54

55

56

58

Sound power level

[dB(A)]

61

62

65

65

Unit dimensions (W x D x H)

[mm]

800x315x545

800x315x545

834 x 328 x 655

834 x 328 x 655

Unit weight (net)

[kg]

34

36

44

46

Refrigerant Type

Type

 

R32

R32

R32

R32

Factory charging

[kg]

1.07

1.1

1.25

1.2

Additional refrigerant charge

[g/m]

20

20

20

20

Pipe connections (diameter)

Liquid pipe

[mm (inch)]

2x6.35(1/4)

2x6.35(1/4)

3x6.35(1/4)

3x6.35(1/4)

Gas pipe

[mm (inch)]

2 x 9.52 (3/8)

2x9.52(3/8)

3x9.52(3/8)

3x9.52(3/8)

Maximum piping length

Total piping length

[m]

40

40

60

60

with a single indoor unit

[m]

25

25

30

30

Maximum level difference

between the outdoor unit and indoor unit.

[m]

15

15

15

15

Between indoor units

[m]

10

10

10

10

Operation range (ambient temperature)

Cooling

[°C]

-15-52

-15-52

-15-52

-15-52

Heating

[°C]

-20-24

-20-24

-20-24

-20-24

TECHNICAL DATA - OUTDOOR UNITS

Multi Split
AUX-M4-36LCLH, AUX-M5-42LCLH

Model

 

AUX-M4-36LCLH

AUX-M5-42LCLH

Number of indoor units

 

4

5

Cooling capacity

[kW]

10.50 (2.5-11.0)

12.00 (2.77-12.7)

[Btu/h]

35826 (8530 - 37532)

40944 (9451 - 43332)

Heating capacity

[kW]

11.00 (2.67-11.2)

13.00 (2.96-13.1)

[Btu/h]

37532(9110-38214)

44356 (10100 - 44800)

Power

[V-,Hz,Ph]

220-240, 50,1

220-240, 50,1

Power consumption in cooling mode

[W]

3950 (680 - 4930)

4450 (750 - 5450)

Power consumption in heating mode

[W]

3150 (530 - 3850)

3750 (600 - 4350)

Energy consumption (cooling and heating)

[A]

17.5/13.96

19.72/16.62

Maximum power consumption

[A]

23.5

24.5

Energy consumption

[kW]

5.3

5.6

SEER/SCOP

[W/W]

6.10 / 4.00 (F)

6.10 / 4.10 (F)

6.15/4.12 (J)

6.14/4.14 (J)

EER / COP

[W/W]

2.66 / 3.49

2.70 / 3.47

Energy efficiency class

Cooling

 

A++

A++

Heating

 

A+

A+

Compressor type

 

rotary

rotary

Air flow

[m3/h]

4000

4200

Sound pressure level

[dB(A)]

61

61

Sound power level

[dB(A)]

68

68

Dimensions unit (W x D x H)

[mm]

985x395x808

985x395x808

Unit weight(net)

[kg]

74

75

Refrigerant Type

Type

 

R32

R32

Factory charging

[kg]

2.3

2.3

Additional refrigerant charge

[g/m]

20

20

Pipe connections (diameter)

Liquid pipe

[mm (inch)]

4x6.35 (1/4)

5x6.35(1/4)

Gas pipe

[mm (inch)]

4x9.52(3/8)

5x9.52(3/8)

Maximum piping length

Total piping length

[m]

80

80

with a single indoor unit

[m]

35

35

Maximum level difference

between the outdoor unit and indoor unit.

[m]

15

15

Between indoor units

[m]

10

10

Operation range (ambient temperature)

Cooling

[°C]

-15-52

-15-52

Heating

[°C]

-20-24

-20-24